Alibaba.com

Verified Supplier | Dongguan Huxin Elect...

Dongguan Huxin Electronics Co., Ltd.

China (Mainland) | Manufacturer | Contact Details
Experience:
Established 2011
1 years OEM
Performance:
Response Rate
Company Feedback

Quick Details

  • Place of Origin: Guangdong, China (Mainland)
  • Brand Name: Deep Sea OEM
  • Model Number: DSE5510
  • Model: DSE5510
  • Brand: Deep Sea OEM
  • Usage: Brushless generator
  • Frequency: 50-60Hz
  • Size: 24.0x17.2x5.7cm
  • Panel cutout: 22.0x16.0cm
  • Weight: 1kg
  • MOQ: 2pcs
  • Factory: Yes
  • Type: DSE5510

Packaging & Delivery

Packaging Details: 1pcs a set in a box.
Delivery Detail: Within 3days after reiceived payment.(Accroding quantity)

Specifications

DSE5510
1.Deep Sea controller DSE5510
2.Genset controller DSE5510
3.control module DSE5510
4.DSE5510, deep sea 5510

 

DSE5510

 

Deep Sea controller DSE5510, Genset controller DSE5510
generator control module DSE5510, DSE5510, deep sea 5510

DSE5510 Introduction:

 

The DSE5510 is an automatic engine control modiule, designed to provide advanced load share functionlity for diesel and gas generating sets that include non-electronic and electronic engines. The module aslo provides excellent engine monitoring and protection features. The modules also share functions include, automatic synchronising with built in synchroscope and closing onto dead bus.Direct and flexible outputs from the module are provided to allow connection to the most commonly used speed governors and automatic voltage regulator. The module has been designed to combine a maximum of 16 generators and 16 mains (utility)supplies up to a maximum of 20 in one system,e.g.16 generators and 4 mains(utility)supplies(DSE5560 required to synchronise with the mains).

The DSE5510 module has the ability to monitor under/over generator volts, over current, under/over generator freqyency, under speed, over speed, charge fail, emergency stop, low oil pressure, high engine temperature, fail to start, low/high DC battery volts, fail to stop, generator short circuit protection, reverse power, generator phase rotation error, earth fault protection, loss of speed signal, fail to open, fail to close, out of sync and MPU open circuit failure, negative phase sequence and loss of excitation.

Main features

 

KEY FEATURES

• Electronic engine capability
• RS232 or RS485 remote communications
• Modbus RTU
• Pin number protected front panel programming
• Engine exercise timer
• Back-lit LCD 4-line text display
• Multiple display languages
• Voltage measurement
• Configurable inputs (9)
• Configurable outputs (5)
• Automatic start
• Manual start
• Audible alarm
• LED indicators
• Built-in governor and AVR control
• Engine history event log
• Engine protection
• Fault condition notification to a designated PC
• Front panel mounting
• PC configuration
• Bus failure detection
• Configurable alarm timers
• Configurable start & stop timers
• Automatic load transfer
• SMS alert messaging
• Front panel mounting
• Remote monitoring
• Magnetic pick-up

 

KEY LOAD SHARE FEATURES

• ROCOF & vector shift
• Automatic starting & stopping of generator on load demand
• Automatic hours run balancing of generator sets
• Dead bus sensing
• Module has the ability to interface with existing load share lines
• Direct communication from the Module to the governor and AVR
• Link up to 16 generators
• Volts & frequency matching
• KW and Kvar load sharing with multiple generators

 

BENEFITS

• Sends SMS messages to engineers to notify specific engine problems (GSM Modem and SIM card required)
• On-site and remote (modem required) module configuration
• In-built engine diagnostics removes the requirement for service equipment
• Full engine protection & instrumentation without the need for additional senders (Electronic engines only)
• Remote monitoring of the module using comprehensive DSE PC software
• License free PC software

 

Specification:

DC SUPPLY

CONTINUOUS VOLTAGE RATING   8V to 35V continuous
CRANKING DROPOUTS
Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V.

This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT  460mA at 12V. 245mA at 24V
MAXIMUM STANDBY CURRENT   375mA at 12V. 200mA at 24V
ALTERNATOR INPUT RANGE   15V(L-N) to 333V AC (L-N) absolute maximum
ALTERNATOR INPUT FREQUENCY    50Hz - 60Hz at rated engine speed (Minimum: 15V AC L-N)
MAGNETIC PICK-UP VOLTAGE RANGE   +/- 0.5V to 70V Peak
MAGNETIC INPUT FREQUENCY  10,000 Hz (max)
CHARGE FAIL/EXCITATION RANGE  0V to 35V

OUTPUTS

START RELAY OUTPUT    16A DC at supply voltage
FUEL RELAY OUTPUT    16A DC at supply voltage
AUXILIARY RELAY OUTPUTS   Three outputs 5A DC at supply voltage  /  Two outputs volt free 8A at 250V AC

BUILT IN GOVERNOR CONTROL  

Fully Isolated
Minimum Load Impedence: 1000Ω
Gain Volts 0V - 10V DC
Offset Volts + / - 10V DC

BUILT IN AVR CONTROL
Fully Isolated
Minimum Load Impedence: 1000Ω
Gain Volts 0V - 10V DC
Offset Volts + / - 10V DC

 

DIMENSIONS

OVERALL
240mm x 172mm x 57mm   /   9.4” x 6.8” x 2.2”
PANEL CUTOUT
220mm x 160mm    /   8.7” x 6.3”

  

 

If you are interested in knowing more about our products, please feel free to contact us. Thanks. We are looking forward to establish a bright and long-term business relationships with you. You will be satisfied with our best quality,competitive price and best services.

 

Dongguan Huxin Electronics Co. Ltd.

Website: www.en.huxindg.com , www.huxindg.cn

 

Buyer Product Name Price Quantity Order Time(GMT+8)

Feedback most closely related to this product:

Email to this supplier
Verified Supplier - Dongguan Huxin Electronics Co., Ltd.
China (Mainland) | Manufacturer | Contact Details
Experience:
Established 2011
1 years OEM
Performance:
Response Rate
Company Feedback

Communicate with Supplier

Ms. Anna Wen
What can I do for you?
Minisite Survey